Automatic relaxation and creep tester, EB 32

The automatic relaxation and creep tester EB 32 is equipped with a liquid circulator for cooling and can cycle between -40 °C and +200 °C, with the same temperature in all 3 test stations. The EB 32 instrument perfoms tests according to ISO 188 method A, ISO 3384-1 method A and B, ISO 3384-2 method A and B, ISO 6914 method A, ISO 8013, and ISO 899-1 as well as ISO 899-2 with modified test specimen (no extensometer required).

By default the EB 32 is delivered with compression plates and 1000 N load cells. Other accessories such as different loadcells, testing in compression in liquid, testing in air in tension and special clamps for testing in creep according to ISO 899-1 and ISO 899-2 can be ordered separately.

If testing at 23 °C is wanted, the test can be performed with the rigs in their raised position in the hood instead of down in the cells of the oven.

The test rigs are based on our relaxation rig EB 02, but here the lowering and raising of the rigs, as well as the compression or tension of the samples, are motor driven by a servo motor.

As the positioning is done by servo motors, the instrument will automatically compensate for the deformation in the load cells. The resolution of the position is 0,0001 mm and the accuracy 0,001 mm.

The test rigs are built into a cabinet made of polycarbonate with aluminium profiles, which provides the same temperature stability around the upper part of the rigs as our other continuous relaxation test systems. The oven is one of our high precision ageing ovens, and meets the international standard ISO 188 method A as well as other technically equivalent standards.

The EC 13 Windows application, which is a part of the EB 32 automatic relaxation and creep tester, helps the user setup the test and it continuously displays the results.

Easy to change between test methods

EB18 software EC13, method selectorBoth testing methods, stress relaxation and creep uses the same accessories. The shifting between the two test methods is done when the EC 13 software is started. Changing between compression and tension consist of a simple rebuilding of the rigs, thoroughly described in the manual.

Note: For the best performance of the instrument, we recommend a placement in an environment with a stable temperature between +10 to +30 °C.

Standards

  • ISO 188 method A
  • ISO 3384-1 method A and B
  • ISO 3384-2 method A and B
  • ISO 6914 method A
  • ISO 8013
  • ISO 899-1 with modification
  • ISO 899-2 with modification
  • other equivalent standards

Temperature range

-40 °C to +200 °C

Important specifications

  • EC 13 software – Required for using EB 32
  • EB 32.01 liquid circulator for cooling
  • Temperature variation in time ± 1 °C
  • Temperature indicator with sensor in each cell (PLC)
  • Temperature controller with 0,1°C set point (PLC)
  • Adjustable upper and lower temperature limits with alarm (PLC)
  • Controlled from a micro PLC, with a colour touch screen
  • Test names can be given in the PLC
  • Special design with controlled air exchange rate and low air speed
  • Built in air pump
  • Alarm for low air pressure (PLC)
  • Improved insulation reduces energy consumption, environmental impact and cost
  • Cooling channels in the casing for low surface temperature
  • Indication of power failure (PLC)
  • Run-time meter (PLC)
  • Countdown timer for each cell (PLC)
  • Alarm history
  • Microfilter for the air which removes 99,99 % of all particles over 0,1 μm

Included with EB 32

  • All-in-one computer (Windows) with monitor, keyboard and mouse
  • Support agreement first year
  • Manual in English
  • Tools such as a stylus pen for the instrument touch screen
  • Accredited calibration including certificate

Optional accessories

For rebuilding the rigs to tension

  • EB 02.02 Grips for testing relaxation in tension, according to ISO 6914
  • EB 02.03 Load cell 100 N for tests in tension, including adapters
  • EB 18-II.01 Clamp for creep test in tension, according to ISO 899-1

For testing in liquids

  • EB 02.01 Container and pressure plate (with a hole in the centre) for measurement in liquids, according to ISO 3384

For flexural creep testing of plastics

  • EB 02.29 Fixture for flexural creep by 3-point loading, according to ISO 899-2

More information

Product brochure: Elastocon – Stress relaxation and creep systems.pdf


Watch Elastocon's video about the automatic relaxation and creep tester